36
Area 1 Area 2
Location Default Location Default
Scheduled Arm Mode [693] 0 [726] 0
Scheduled Arm Days [694] H-00 [727] H-00
Arm Time Sun (hr:min) [695:696] 00:00 [728:729] 00:00
Arm Time Mon (hr:min) [697:698] 00:00 [730:731] 00:00
Arm Time Tues (hr:min) [699:700] 00:00 [732:733] 00:00
Arm Time Wed (hr:min) [701:702] 00:00 [734:735] 00:00
Arm Time Thurs (hr:min) [703:704] 00:00 [736:737] 00:00
Arm Time Fri (hr:min) [705:706] 00:00 [738:739] 00:00
Arm Time Sat (hr:min) [707:708] 00:00 [740:741] 00:00
Latch Key User ID [709] 0 [742] 0
Latch Key Days [710] H-00 [743] H-00
Latch Key Window (min) [711] 0 [744] 0
Latch Time Sun (hr:min) [712:713] 00:00 [745:746] 00:00
Latch Time Mon (hr:min) [714:715] 00:00 [747:748] 00:00
Latch Time Tues (hr:min) [716:717] 00:00 [749:750] 00:00
Latch Time Wed (hr:min) [718:719] 00:00 [751:752] 00:00
Latch Time Thurs (hr:min) [720:721] 00:00 [753:754] 00:00
Latch Time Fri (hr:min) [722:723] 00:00 [755:756] 00:00
Latch Time Sat (hr:min) [724:725] 00:00 [757:758] 00:00
Area Schedules Default Table
NOTE
The Latchkey Time Window cannot cross over the Midnight boundary. During the Time Window,
the Control Station will chime once a minute until the user passcode is entered or the Time Window
has expired, whichever comes first.
Latch Key Schedules
A Latch Key User ID is used to determine which user passcode must be entered on selected Latch Key Days. The user
passcode must be entered within a time window. If the user passcode is not entered during the Time Window, a Latch key
Supervision event will be posted in the Event Log to be reported.
For example, if Monday is a Latch Key Day and the Latch Key Time for Monday is 14:30 with a thirty minute Time
Window and the Latch Key User ID is not entered between 14:00 and 15:00 hours, then a Latch Key Supervision event will
be posted at 15:00 hours.