35
Recent Closing Code 00 to FF Code sent in addition to a burglar alarm event if the alarm occurs within two
minutes after exit time expires.
Latchkey Supervision Code 00 to FF Code sent when the latchkey code is not entered during the programmed time
window.
User on Premises Code 00 to FF Code sent when the User on Premises (Authority Level 12) passcode is entered
to disarm the system or perform the access operation.
Comm Test Not Norm Code 00 to FF Code sent at the comm test time-of-day in place of the comm test report when a
trouble condition is present. If this report code is set to 00, a normal comm test
event is transmitted.
Comm Test Report Code 00 to FF Code sent at the comm test time-of-day when no trouble conditions are present.
Transmitted at power-up, if Test On Power-Up is enabled (see Section 3.2.7).
Implies proper operation of the communicator and the telephone line.
AC Fail Report Code 00 to FF Code sent when the control has lost the primary AC input. The delay time
before this report is transmitted is located in Section 3.2.6.
AC Restore Report Code 00 to FF Code sent when the AC primary power has been restored.
Low Battery Report Code 00 to FF Code sent when the control detects a low battery voltage reading of 11.3 VDC
or less.
Battery Restore Code 00 to FF Code sent when the low battery condition has been restored.
Bell Fault Report Code 00 to FF Code sent when the control panel detects a Bell Fault.
Bell Restore Report Code 00 to FF Code sent when the Bell Fault trouble is restored.
Comm Restore Report Code 00 to FF When the control is unsuccessful in reporting an event, the fail to communicate
(local trouble) displays. If a subsequent report of any type is successful, the
control also reports this code.
Memory Error Report Code 00 to FF Code sent when the internal memory check finds an unauthorized change in the
value of one or more of the programming options.
Local Prog Begin Code 00 to FF Code sent when a program function map is initiated at the control site.
Local Prog End Code 00 to FF Code sent after programming mode is terminated at the installation site. This
occurs 255 seconds after exiting programming mode or by holding the CLEAR
key for three seconds.
RPM End Report Code 00 to FF Code sent when an RPM session has been completed normally.
RPM Denied Report Code 00 to FF Code sent when an unauthorized RPM session is attempted (i.e.: improper ID
code or access device).
RPM Abort Report Code 00 to FF Code sent when an RPM session is aborted. If an alarm event requiring a
report to the Central Station occurs during an RPM session, the control may
abort the session to report the event.
Missing Keypad Code 00 to FF Code sent when a supervised Control Station is removed or fails to respond to
system polling.
Restore Keypad Code 00 to FF Code sent when a missing Control Station is restored to the data bus.
RF Jamming Report Code 00 to FF Reserved for future use.
RF Channel Clear Code 00 to FF Reserved for future use.
RF Keyfob Low Battery Code 00 to FF Reserved for future use.
Automatic Arming
If automatic arming is enabled, the control produces a warning signal at the appropriate Control Station(s) once every minute
beginning ten minutes prior to the event. During this warning, the same control station(s) may display a visual indication of the
impending action and the amount of time remaining. This allows the user ample warning to exit or override the impending
action. Auto Arming time may be extended by one hour during each ten minute warning period (but not past midnight) using the
Delay Auto Arming function. The user can also abort the scheduled arming for that day through User Level programming. (See
the appropriate User Guide). Auto Arming arms the control in the AWAY, STAY, or NIGHT mode with normal exit time.
3.2.13 Area Schedules Description
WWW.DIYALARMFORUM.COM