25
Condition Output Becomes Active When:
Fire Alarm A Fire or Verified Fire zone or an ‘A’ Key is in alarm.
Fire Supervisory A zone defined as Fire Supervisory is in alarm.
Duress A Duress code has been used. To turn off, press the CLEAR key for 3 seconds.
Panel Low Battery A Panel Low Battery trouble condition occurs.
Failed to Comm A Failed to Comm trouble condition occurs.
Telco Line Fault A Telco Line Fault trouble condition occurs.
Telco Line Seized The system seizes the telephone line for an RPM connection or prior to making a call to the Central Station.
Ground Start A Telco ground start circuit is triggered for one second.
Burglar Alarm A Burglar or a Burglar Tamper defined zone is in alarm.
Holdup Alarm A Holdup zone or an ‘B’ Key is in alarm.
Auxiliary Alarm An Auxiliary zone or an ‘C’ Key is in alarm.
Bell Output Trigger In the same manner as the Bell Output (see Section 3.2.5.1).
Violation A Fire, Fire Supervisory, Burglar, Auxiliary, Visible Holdup or Burglar Tamper is in alarm.
Ready The area is ready to arm.
Armed AWAY The area has been armed in the AWAY mode.
Armed STAY The area has been armed in the STAY mode.
Armed NIGHT The area has been armed in the NIGHT mode.
Armed & Exit Time Expired The area has been armed in any way and the exit time has expired.
Exit Time The exit time starts in its area due to an AWAY, STAY, or NIGHT arm. The output will go ON STEADY
until the last ten seconds, then it will PULSE for the last ten seconds. When the Exit Time expires, it will go
ON STEADY for two seconds.
Entry Time The entry time starts in its area. The output will stay ON STEADY until the last ten seconds of entry time.
During the last ten seconds of entry time, it will PULSE.
Pre-Alarm Warning Time Any of its areas are in Pre-Alarm Warning Time. The output will PULSE when any of its areas are in Pre-
Alarm Warning Time.
Annunciation The Annunciation output operates like a combination of the Exit Time, Entry Time, and Pre-Alarm Warning
Time outputs. When the exit time starts in its area due to an AWAY, STAY, or NIGHT arm, the output will go
ON STEADY until the last ten seconds. During the last ten seconds, it will PULSE and when the exit time
expires, it will go ON STEADY for two seconds. When the entry time starts in its area, the output will go ON
STEADY until the last ten seconds of entry time. During the last ten seconds, it will PULSE. When in Pre-
Alarm Warning Time, the output will PULSE.
Auto Arm Warning The timer activates for 3 seconds for each minute of the ten minutes left before Auto-Arming occurs. It will
also activate at one minute and two minutes until before an Exit Arm occurs.
Closing Ringback A Closing Report due to an AWAY arm from a Control Station or keyswitch has been successfully transmit-
ted to the Central Station.
Trouble A System Trouble condition is present. (Following this table is a list of Trouble Conditions.)
Chime A Disarmed Chime Always Burglar zone in any of its areas is violated, a Disarmed Perimeter (Arm on STAY
& Arm on NIGHT) Burglar zone in any of its areas is violated and that area has Chime Enabled.
Universal A Universal or Universal Logged zone is violated. (See Section 3.3, Programming Note 16.)
Listen-In An alarm event is reported to the Central Station from one of the output’s areas. (See Section 3.3, Program-
ming Note 11.)
Lamp Trigger Any of its areas are in exit time, entry time and five minutes after entry time. The Output will go ON
STEADY when its areas are in entry time and will stay ON STEADY until five minutes after entry time
expires or five minutes after disarm (whichever is shorter). (See Section 3.3, Programming Note 17.)
Key 4 Output ENTER + Key #4 is pressed on a keypad primary to its area. May be used to toggle an output ON/OFF.
Key 5 Output ENTER + Key #5 is pressed on a keypad primary to its area. May be used to toggle an output ON/OFF.
The programmable outputs will be activated according to their Output Condition listed in the following table. The output
will go ON STEADY for the following conditions unless otherwise specified in the table.
3.2.5.2 Programmable Output Activation