28
Used to enable the control digital communicator for event
reporting. Must be set to 0 if phone line is disconnected. If line is
disconnected and a trouble condition occurs, the control station
will display ‘Failed to Communicate’ and/or ‘Phone Line Fault’
trouble until it is disabled.
Allows the auto comm test to be skipped if any signal has been
transmitted to the Central Station since the last auto comm test.
Causes a communicator test to be initiated immediately upon
system power up. Does not affect days between tests counter.
If enabled, the system will automatically dial “*70D” (or “1170D”
if pulse dialing) prior to dialing a telephone number. This will
temporarily disable the Call Waiting beeps during a phone call.
Sets the hour and minute in military format for the auto communi-
cator test.
Sets the time intervals in days for the auto communicator test. A
setting of 0 disables Automatic Comm Test Reporting. Days until
next comm test may be manually adjusted by control station. See
Section 3.1.7.
Time in seconds between a failed dial attempt to a Central Station
and the next dial attempt.
Transmission format to be used when the communicator dials
telephone #1. See Section 3.3, Programming Note 14.
Transmission format to be used when the communicator dials
telephone #2. See Section 3.3, Programming Note 14.
Sets the type of dialing.
“US Rotary” uses North American Standard (60/40) make/ break
ratio pulses.
TT (Touchtone®) uses industry standard DTMF tones.
Touchtone® is a trademark of AT&T.
“Foreign Rotary” uses 67/33 make/break ratio pulses, typical of
foreign countries.
Item Valid Range Description
The following table refers to programming locations 322 through 336:
3.2.7 Communicator Data Description
Enable Communicator 0 = No
1 = Yes
Enable Skip Test 0 = No
1 = Yes
Power-up Comm Test 0 = No
1 = Yes
Disable Call Waiting 0 = No
1 = Yes
Comm Test Time of Day 00:00 to 23:59 HH:MM
Days Between Comm 0 = Disable, 1 to 255 days
Tests
Time Between Calls 0 to 255 seconds
T1 Trans Format 0 = Pulsed 20 Baud - Non-Extended
1 = Pulsed 20 Baud - Extended
2 = Pulsed 40 Baud - Extended
3 = Contact ID
4 = Non-Telco Contact ID
T2 Trans Format 0 = Pulsed 20 Baud - Non-Extended
1 = Pulsed 20 Baud - Extended
2 = Pulsed 40 Baud - Extended
3 = Contact ID
4 = Pager
Dialer Type
0 = US Pulsed
1 = Touchtone®
2 = Foreign Pulse
Loc Default Loc Default
Enable Communicator [322] 1 T1 Trans Format [330] 3
Enable Skip Test [323] 0 T2 Trans Format [331] 3
Power-up Comm Test [324] 0 Dialer Type [332] 1
Disable Call Waiting [325] 0 T1 Dial Attempts [333] 5
Comm Test Time of Day (hr:min) [326: 327] 00:00 T2 Dial Attempts [334] 5
Days Between Comm Tests [328] 0 On-Hook Time (sec) [335] 5
Time Between Calls (sec) [329] 5 Off-Hook Time (sec) [336] 3
Communicator Data Default Table