15
AWAY Exit Delay Time 0 to 255 seconds
STAY & NIGHT Exit 0 to 255 seconds
Time
Entry Delay Time 1 0 to 255 seconds
Entry Delay Time 2 0 to 255 seconds
Pre-Alarm Warning Time 0 to 255 seconds
‘B’ Key Alarms 0 = No Keypad Sounder or Bell
Output (invisible)
1 = Keypad Sounder Only
2 = Keypad Sounder and Bell Output
‘C’ Key Alarms 0 = No Keypad Sounder or Bell
Output (visible)
1 = Keypad Sounder Only
2 = Keypad Sounder and Bell Output
Closing Ringback 0 = Ringback Output
1 = Ringback Output and Keypads
2 = Ringback Output, Bell Output and
Keypads
Burglar Audible Lockout 0 = No Lockout
1 to 15 = Alarms for an Area
Swinger Shunt 0 = No Shunt
1 to 15 = Violations for a Zone
Time in seconds for all Burglar zones, may be audibly
annunciated. (See Section 3.3, Programming Note 1.)
Time in seconds for all Burglar zones, always silent.
Time in seconds to enter Burglar zones defined as Delay #1,
may be audibly annunciated.
Time in seconds to enter Burglar zones defined as Delay #2,
may be audibly annunciated.
Time in seconds to correct a false alarm, always audible. (See
Section 3.3, Programming Note 2.)
Defines the annunciation of an alarm activated by the Police
key.
Defines the annunciation of an alarm activated by the Medical/
Emergency key.
Determines how the system annunciates the successful
transmission of an AWAY closing report to the Central Station.
Determines the number of times that a Bell Output may be
activated during an armed cycle, resets with disarm.
Determines the number of violations that may occur from an
armed burglar zone before that zone is automatically bypassed.
The following table refers to programming locations 1 through 22.
3.2.1 Area Data Descriptions
Item Valid Range Description
Area Data Default Table
AREA 1 AREA 2
Location Default Location Default
AWAY Exit Time (sec) [1] 60 [12] 60
STAY/NIGHT Exit Time (sec) [2] 60 [13] 60
Entry Time 1 (sec) [3] 20 [14] 20
Entry Time 2 (sec) [4] 40 [15] 40
Pre-Alarm Time (sec) [5] 0 [16] 0
‘B’ Key Alarms [6] 2 [17] 2
‘C’ Key Alarms [7] 1 [18] 1
Closing Ringback [8] 0 [19] 0
Burglar Audible Lockout [9] 0 [20] 0
Swinger Shunt [10] 0 [21] 0
Area Attributes [11] H-09 [22] H-09
WWW.DIYALARMFORUM.COM