MOOSE ZXSSD Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Sistemas de segurança - controlo de acesso MOOSE ZXSSD. MOOSE ZXSSD User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
ZX400/ZX410
SECURITY SYSTEM CONTROL
PROGRAMMING GUIDE
WWW.DIYALARMFORUM.COM
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - ZX400/ZX410

1ZX400/ZX410SECURITY SYSTEM CONTROLPROGRAMMING GUIDEWWW.DIYALARMFORUM.COM

Página 2

10After entering programming mode, press the ‘2’ key for Set Clock programming. The Control Station will go into clock setmode.The SSD Control Statio

Página 3

11While the Control Station is displaying the value at a location, you can enter digits to change the value at that location. Thenew value is display

Página 4

12Key #1 0123456789: ; <=>?@Key #2 A B CKey #3 D E FKey #4 G H IKey #5 J K LKey #6 M N OKey #7 P Q R SKey #8 T U VKey #9 W X Y Z [ ù ] ^ _Key #0

Página 5

13If the ENTER or CLEAR key is pressed and no changes have been made, the Control Station will return to the Zone IDprompt. If the CLEAR key is press

Página 6

14To edit the Function Map, press the PROGRAM (9) key, enter the installer passcode, and press the ‘3’ key to select the EditFunction Map programming

Página 7

15AWAY Exit Delay Time 0 to 255 secondsSTAY & NIGHT Exit 0 to 255 secondsTimeEntry Delay Time 1 0 to 255 secondsEntry Delay Time 2 0 to 255 second

Página 8

16Enter For: 0123456789ABCDEFFirst DigitAll Features Below Disabled *Two Button Arm ********Double Button Press Arm * * * * * * * *Open After Alarm **

Página 9

17KEYPAD 1 KEYPAD 2 KEYPAD 3 KEYPAD 4 KEYPAD 5 KEYPAD 6Loc Default Loc Default Loc Default Loc Default Loc Default Loc DefaultKeypad Type LED LED SSD

Página 10 - WWW.DIYALARMFORUM.COM

183.2.3 Zone Data DescriptionsZone Type Area Expansion Zone Burglar Zone Attribute Zone AttributeLoc Default Loc Default Loc Default Loc Default Loc D

Página 11

19Item Valid RangeZone Type 0 = Not Used1 = Burglar2 = 24 Hour Fire3 = 24 Hour Holdup4 = 24 Hour Auxiliary5 = Momentary Keyswitch (ArmAWAY/Disarm)6 =

Página 12

2WWW.DIYALARMFORUM.COM

Página 13

20Enter For: 0123456789ABCDEFFirst DigitStandard (all below disabled) *Chime Always ********Verifying * * * * * * * *Self-Verifying **** ****Sentry Te

Página 14

21 Code Authority Level Operation Area Code Authority Level Operation AreaDefault Loc Default Loc Default Default Loc Default Loc DefaultUser 01 1234

Página 15

22** For High Level Security applications onlyAccess from Keypad *********** **Chime Enable/Disable ***********Silence Bell without Disarm * * *Arm (

Página 16

23This data block is used to assign the programmable outputs. The control is equipped with one programmable on-boardoutput (PGO1) and one bell output

Página 17

24If the Output Condition is “Ready”, “Armed AWAY”, “Armed STAY”, “Armed NIGHT”, “Armed & Exit Time Expired”,“Exit Time”, “Entry Time”, “Annunciat

Página 18

25Condition Output Becomes Active When:Fire Alarm A Fire or Verified Fire zone or an ‘A’ Key is in alarm.Fire Supervisory A zone defined as Fire Super

Página 19

26The list of Trouble conditions are as follows:AC Power Failure Low Battery Memory ErrorCommunication Failure Silenced Fire Alarm Fire SupervisorySmo

Página 20

27NOTE: If the First Digit entered is ‘1’, it must be entered as ‘01’. A = 10; B = 11; C = 12; D = 13; E = 14; F = 15System Attribute TableDelay Bef

Página 21

28Used to enable the control digital communicator for eventreporting. Must be set to 0 if phone line is disconnected. If line isdisconnected and a t

Página 22

29Location DefaultTelephone 1 (16 digits) [337 - 352] all F’sTelephone 2 (24 digits) [353 - 376] all F’sRPM/2 Pro Phone (16 digits) [377 - 392] all F’

Página 23

3Table of ContentsOperating The System ...

Página 24

30Item Valid Range DescriptionTelephone 1 Account No.Telephone 2 Account No.6 Hex Digits6 Hex DigitsAccount number used when dialing telephone #1. Se

Página 25

31Fire Phone No.Note: These events are reportedusing Area 1 account codes only.Systems Events Phone No.Note: These events are reportedusing Area 1 acc

Página 26

32Alarm Restore Bypass TroubleLoc Default Loc Default Loc Default Loc DefaultZone 01 [435] H-31 [436] H-E3 [437] H-AB [438] H-F3Zone 02 [439] H-32 [44

Página 27

33Close Open Close OpenLoc Default Loc Default Loc Default Loc DefaultUser 01 [555] H-C1 [556] H-B1 User 26 [605] H-CF [606] H-BFUser 02 [557] H-C2 [5

Página 28

34Loc Default Loc Default‘A’ Key Report Code [655] H-19 Comm Test Report Code [674] H-00‘B’ Key Report Code [656] H-29 AC Fail Report Code [675] H-FA‘

Página 29

35Recent Closing Code 00 to FF Code sent in addition to a burglar alarm event if the alarm occurs within twominutes after exit time expires.Latchkey S

Página 30

36Area 1 Area 2Location Default Location DefaultScheduled Arm Mode [693] 0 [726] 0Scheduled Arm Days [694] H-00 [727] H-00Arm Time Sun (hr:min)

Página 31

37NOTE: If the First Digit entered is ‘1’, it must be entered as ‘01’. A = 10; B = 11; C = 12; D = 13; E = 14; F = 15Scheduled Arming and Latch Key

Página 32

38Location DefaultInstaller Passcode [759 - 762] 9632Call 2 Timer (sec) [763] 0Auto Answer Ring Count [764] 5Enable RPM [765] 1Enable Power Up Program

Página 33

39Note 1: Restarting Exit TimeIf an exit time is counting down from an AWAY arming, the exit time may be automatically restarted once to reduce fals

Página 34

41Operating The System1.1 IntroductionThe Moose ZX400/ZX410 Security System incorporates the most desired operational features available today. The Z

Página 35

40Note 6: Verifying or Self-Verifying Burglar ZonesIf an armed Verifying Burglar zone is violated, then a forty second Verification Timer is started.

Página 36

41Note 10: Senior WatchThe Senior Watch attribute may only be used with Burglar, Critical Condition Monitor, Universal, and Universal Logged zones. I

Página 37

42Note 12: Delay Before Dial TimeThe Delay Before Dial Time is used as the time that a user has after a Burglar, Holdup, or Auxiliary Alarm from a zo

Página 38

43bus. The interface device will send an acknowledgment to the system upon successful transmission of an event. The telephone number willnot be used

Página 39

44Event Type CID Code Event Source‘A’ Key Fire Alarm 1115 500 + Keypad (1 - 6)Zone Fire Alarm 1110 Zone (1 - 30)Zone Fire Supervisory 1200 Zone (1 - 2

Página 40

45Zone Auxiliary Trouble Restore 3370 Zone (1 - 28)Zone Other Trouble Restore 3370 Zone (1 - 28)Senior Watch Trouble Restore 3641 Zone (1 - 28)Zone No

Página 41

46UL has established certain requirements which pertain to the installation, use, and programming of this equipment. The local AuthorityHaving Jurisd

Página 42

47IndexA‘A’ Key 17, 24, 25, 34, 44AC Cycles 27AC Power Failure 8, 26ACCESS Key 7Account Code 11, 33, 42Alarm Abort 27Alarm Indicator 24, 25, 26

Página 43

48RREADY 4Receiver Compatibility 29Remote Connect 10, 22Remote Programming 8, 10, 38Report Code 12, 32, 33, 34, 35, 42, 46Reset Smoke Key 7RF Si

Página 44

49NotesWWW.DIYALARMFORUM.COM

Página 45

5FIGURE 1-1 System Control Stations1.3 Control Station OverviewFor SSD, LED, LCD, and VFD Control Stations:Away, Stay, and Night Keys These keys, f

Página 46

50NotesWWW.DIYALARMFORUM.COM

Página 47

51WWW.DIYALARMFORUM.COM

Página 48

52sentrol controls groupPO Box 29041510 Tate Blvd. SEHickory, NC 28603Sales: 800.547.2556Fax: 503.691.7566Technical Support: 800.800.2027MOOSEa pro

Página 49

6All Control Station function keys (except the View Info Key) require that the function key be pressed followed by a validpasscode. The passcode’s au

Página 50

7KEY #6 CHIME KEYThis key turns the chime function on or off for a particular area.KEY #7 RST SMOKE KEYThis key resets all latched smoked detectors an

Página 51

8The control may be divided (partitioned) into two independent areas. To the customer, each area appears to be a full-featured system. This allows o

Página 52 - 64812702B

9Figure 2-1 Area PartitioningEach area can be programmed to control separate outputs with a dedicated audible or annunciator. It is also possible t

Comentários a estes Manuais

Sem comentários